I recently became the proud (second) owner of two Vestax PDX-2000
turntables with Ortofon Concorde DJS cartridges and styli, and great as they are, one of the cartridges has been ripping ugly holes in my sets - in many positions in the tone-arm it emits a loud mains buzz and no music at all in the left channel, while the right channel is unaffected. It will only relent after large (a lot more than a few weeks ago) amounts of fiddling with its screw-holder (on the tonearm). The problem obviously seems to be the connection between the cartridge and the tonearm, and if I swap the cartridges, the cartridge carries the problem with it, the second cartridge is always fine. Visually though, both look completely identical. Does anyone have any idea what I could do about this besides shelling out £50 for a new cartridge? I tried cleaning the connection with toothpaste (stop that s******ing at the back) as recommended in one of these forums and it seemed to help for a bit, but only for a few hours. |
#2
![]() |
|||
|
|||
![]()
That's a very common problem with Ortofon integrated carts. The only sure
cure, is new carts. Shure, Stanton, or Ortofon if they use headshells. FWIW I use Shure SC35C carts, in Technics headshells. "Tim Freeman" wrote in message om... I recently became the proud (second) owner of two Vestax PDX-2000 turntables with Ortofon Concorde DJS cartridges and styli, and great as they are, one of the cartridges has been ripping ugly holes in my sets - in many positions in the tone-arm it emits a loud mains buzz and no music at all in the left channel, while the right channel is unaffected. It will only relent after large (a lot more than a few weeks ago) amounts of fiddling with its screw-holder (on the tonearm). The problem obviously seems to be the connection between the cartridge and the tonearm, and if I swap the cartridges, the cartridge carries the problem with it, the second cartridge is always fine. Visually though, both look completely identical. Does anyone have any idea what I could do about this besides shelling out £50 for a new cartridge? I tried cleaning the connection with toothpaste (stop that s******ing at the back) as recommended in one of these forums and it seemed to help for a bit, but only for a few hours. |
#3
![]() |
|||
|
|||
![]()
This reads like an open ground line in the left channel. Perhaps at the
point where the cartridge connects to the shell? Be very careful with the connectors between the cartridge and shell (if that is how the Ortofon is connected) because I have seen the plastic on a Shure cartridge disintegrate at this location after some 20-30 years. Tim Freeman wrote: I recently became the proud (second) owner of two Vestax PDX-2000 turntables with Ortofon Concorde DJS cartridges and styli, and great as they are, one of the cartridges has been ripping ugly holes in my sets - in many positions in the tone-arm it emits a loud mains buzz and no music at all in the left channel, while the right channel is unaffected. It will only relent after large (a lot more than a few weeks ago) amounts of fiddling with its screw-holder (on the tonearm). The problem obviously seems to be the connection between the cartridge and the tonearm, and if I swap the cartridges, the cartridge carries the problem with it, the second cartridge is always fine. Visually though, both look completely identical. Does anyone have any idea what I could do about this besides shelling out £50 for a new cartridge? I tried cleaning the connection with toothpaste (stop that s******ing at the back) as recommended in one of these forums and it seemed to help for a bit, but only for a few hours. |
#4
![]() |
|||
|
|||
![]()
I've seen lots of defective Ortofons - open coils inside.
Mark Z. "Tim Freeman" wrote in message om... I recently became the proud (second) owner of two Vestax PDX-2000 turntables with Ortofon Concorde DJS cartridges and styli, and great as they are, one of the cartridges has been ripping ugly holes in my sets - in many positions in the tone-arm it emits a loud mains buzz and no music at all in the left channel, while the right channel is unaffected. It will only relent after large (a lot more than a few weeks ago) amounts of fiddling with its screw-holder (on the tonearm). The problem obviously seems to be the connection between the cartridge and the tonearm, and if I swap the cartridges, the cartridge carries the problem with it, the second cartridge is always fine. Visually though, both look completely identical. Does anyone have any idea what I could do about this besides shelling out £50 for a new cartridge? I tried cleaning the connection with toothpaste (stop that s******ing at the back) as recommended in one of these forums and it seemed to help for a bit, but only for a few hours. |
Reply |
Thread Tools | |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Linn Troika Moving Coil Cartridge | Marketplace | |||
I think I bought the wrong cartridge | High End Audio | |||
Phono cartridge upgrade for Stanton Str8-20 (cheap turntable)? | Audio Opinions | |||
ortofon OM10 Broken can anyone help!! | High End Audio | |||
Kenwood KD-2055 Marble Base Turntable, Shure Cartridge, | Marketplace |