Home |
Search |
Today's Posts |
|
#1
![]()
Posted to rec.audio.tech,rec.audio.pro,comp.dsp
|
|||
|
|||
![]()
"davew" wrote in message
The VU meter is basically a bridge rectifier followed by a low pass filter. So it's mean rectified, not mean squared. So a 1dB difference for pure tone. We don't tend to use rms or mean whatever when talking about audio levels though, we just say "level" and that seems to be good enough. It's understood that when you reach 0dBFS you're in trouble shortly thereafter. http://www.allaboutcircuits.com/vol_2/chpt_1/3.html " For RMS measurements, analog meter movements (D'Arsonval, Weston, iron vane, electrodynamometer) will work so long as they have been calibrated in RMS figures. Because the mechanical inertia and dampening effects of an electromechanical meter movement makes the deflection of the needle naturally proportional to the average value of the AC, not the true RMS value, analog meters must be specifically calibrated (or mis-calibrated, depending on how you look at it) to indicate voltage or current in RMS units. The accuracy of this calibration depends on an assumed waveshape, usually a sine wave. " IOW, ordinary passive meters are not True RMS meters without a lot of help. The averaging function is produced mechanically, by the mass of the moving parts of the meter If you want to make a passive analog meter that properly reads True RMS, it must use a movement that responds to the square of the applied voltage, and is nonlinearly calibrated to indicate the square root of the applied voltage. A meter that uses the applied voltage to establish both the magnetic field around its armature, and also the magnetic field produced by the armature; will respond to the square of the applied voltage. With this kind of meter, doubling both voltages (which would ordinarly be based on the same signal) will interact to produce an attraction or repulsion that quadruples. The pointer will deflect 4 times further, and the nonlinear calibration of the scale will provide the square root function. Most meters use a permanent magnet to establish the magnetic field around the armature because this makes it easier to produce a sensitive meter. They will then respond more or less linearly to the intensity of the applied voltage. Therefore a proper True RMS meter will probably not be the most sensitive meter around. Passive True RMS meters were widely used in the days before complex active electronic circuits became a practical means to accomplish the same end. I have one that was sold by RCA back in the day for measuring power line voltage, which has the expected highly nonlinear scale. |
Reply |
Thread Tools | |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
dBFS | Pro Audio | |||
Line Input Level for 0 dBFS? | Pro Audio | |||
dBfs scales, EBU r68 or DIN ? | Pro Audio | |||
dBfs scales, EBU r68 or DIN ? | Pro Audio | |||
Classical program ff = ?dbFS | Pro Audio |