RightMark Analyzer Program
On Mar 25, 12:32 pm, Mike Rivers (that's me!)
wrote:
When the level is high enough so that
the test will run, the interchannel crosstalk light on the RightMark
level setting screen keeps going on and off.
I should add that in a crosstalk measurement made by recording with a
signal on one channel and a shorting plug in the other channel's input
connector, the crosstalk on playback was rather high, with the
"unrecorded" channel measuring about 45 dB lower than the recorded
channel, at 200 Hz and 10 kHz. Spec is -77 dB or so at 1 kHz. So maybe
this one is broken, but that wouldn't explain the poor frequency
response that RMAA shows.
|