MK III biaset zoomz to 26v during warmup
I'm rebuilding a pair of MK III's. Just now working on the first.
My plan was to replace all tubes AND:
-1 Replace selenium stack w/ diode & bias caps/resistors with a kit from
Uncle Neddy. Test voltages.
-2 Replace quad cap with triple cap + 1 cap with another kit from Ned. Test
voltages.
-3 Replace driver board with stuffed board from Classic Valves. Test
voltages. Enjoy some Dave Brubeck on my rebuild 60 honkin' watt amps.
Of course, I never took baseline voltage measurements (for I am RAT Boy...
and I knows it all). I replaced the bias circuit (being very careful to get
it all wired back correctly). Using original tubes, I powered it up and
checked the biaset... 1v, 1.9v 2v, 4v, 26v!!! PULL THE PLUG!
I powered it up again and began to check the voltages and compare them to
those listed in manual... 5AR4 voltages are OK on pins 4 & 6 but pins 2 & 8
are sky high. PULL THE PLUG!!!
Replaced the Quad filter with Ned's (triple + 1) kit... same issue.
Is my PT fried? What should resistances at PT leads be? Could the choke be
causing this? Ideas?
|