Bringing up my hifi after 3 year storage
Hi all, haven't been here in a long time.
My system has been in storage for 3 years and I need to wake it all up. 3 years ago, I was in a similar situation and a local retired engineer did it all for me but he can no longer do it. I have a McIntosh MC240, Marantz 8B, Conrad Johnson PV-5, Scott 350B tuner. I have a Variac. But the engineer explained to me that it's not just a matter of slowly bringing up the voltage on each piece, though I do not remember details nor do I understand the electronics well. Can anybody give me some directions, or point me to a place that can walk me though it? Even if I can call somebody in the United States, maybe they can give me some guidance, or maybe I can arrange to pay them. I won't touch it til I'm sure, as the engineer told me I can take out transformers. Thanks very much, Jim Kroger jkk251 at gmail.com |
#2
Posted to rec.audio.tubes
|
|||
|
|||
Bringing up my hifi after 3 year storage
On Dec 4, 10:57*pm, JimKroger wrote:
Hi all, haven't been here in a long time. My system has been in storage for 3 years and I need to wake it all up. 3 years ago, I was in a similar situation and a local retired engineer did it all for me but he can no longer do it. I have a McIntosh MC240, Marantz 8B, Conrad Johnson PV-5, Scott 350B tuner. I have a Variac. But the engineer explained to me that it's not just a matter of slowly bringing up the voltage on each piece, though I do not remember details nor do I understand the electronics well. Can anybody give me some directions, or point me to a place that can walk me though it? Even if I can call somebody in the United States, maybe they can give me some guidance, or maybe I can arrange to pay them. I won't touch it til I'm sure, as the engineer told me I can take out transformers. Thanks very much, Jim Kroger jkk251 at gmail.com Not sure where you are getting your advice... 3 years is not long if they worked back them. Anyway, pull out all the tubes (and any s/s rectifier - I did not check your models for these things) and run up the power slowly - check all AC voltages as you go. Likely all OK. Put back the rectifier and bring it up very slowly, again on the variac, while monitoring the DC B+ voltage. I generally let them sit for a while at, say, 60 - 70 VAC input to let the caps reform a bit, if needed. It's a good idea to have a 1 or 2 amp fuse in the AC supply for all tests. If all OK put back all the tubes and repeat. If all OK, no smoke, normal voltages... then they should work. If not, it's into forensics! Above is a bit brief as I'm being called for dinner! If in doubt, get an expert in! Usual disclaimers... HV can be lethal, etc. Cheers, Roger |
#3
|
|||
|
|||
|
#4
|
|||
|
|||
|
#5
Posted to rec.audio.tubes
|
|||
|
|||
Bringing up my hifi after 3 year storage
It is generally better to reform caps with a current limited DC
supply directly rather than using a Variac through the main supply itself especially in equipment with tube rectifiers. |
Reply |
Thread Tools | |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
New year, new hifi.. | High End Audio | |||
Pooling Storage and adding RAID to edit ProTools over a SAN with FastStream Storage Controller? | Pro Audio | |||
bringing a little sunshine and joy into our lives | Pro Audio | |||
bringing a little sunshine and joy into our lives | Pro Audio | |||
Bringing car audio accross the border... | Car Audio |