On Wed, 14 May 2008 12:00:03 -0500, Bob Simon
wrote:
I have a McIntosh 2100 that was performance certified in 1976 at a
clinic. Now it needs service - one of the channels intermittently
drops.
Clean the switches and controls. Pay special attention to
the speaker on/off switch. If cleaning with Caig MCL doesn't
make it operate reliably, replacements are available from Mc.
It's also a very good idea to remove the driver cards
and to clean their contacts. Just a very, very, very
light coating of Caig on the board contacts and re-insert.
Do they still have those free clinics?
Sadly, Davey O'Brien has been gone these several years. Nobody
else was willing to do the gig.
All good fortune,
Chris Hornbeck